Qingdao Junray Intelligent Instrument Co.,Ltd.

Armorum tutela

  • ZR-1070  Microbial penetration experiment system

    ZR-1070 Systema experimentum subtilitatis microbialis

    In ZR-1070 systematis gasi principii generationis ratio consistit, principale corpus deprehensio, systematis tutelae et temperantiae systematis. Componitur ex serie partium, quae ad acumen microbialem adhibentur in sicco experimentum operandi linteum, operandi vestes et vestes mundas. .

  • Mask Bacterial Filtration Efficiency (BFE) Tester

    Mask Bacterial Efficientia Filtration (BFE) Tester

    Clavis specificationum exemplaris ZR-1000 larva bacteria filtrationis efficientiae probatoris (BFE) non solum cum requisitis B.1.1 in YY0469-2011sed etiam metus ASTMF2100, ASTMF2101 et signis Europae EN14683 occurrit.

  • ZR-1311 Salt Aerosol Generator

    ZR-1311 Salis Aerosol Generator

    ZR-1311 sal aerosol generans instrumentum speciale est, collisonum collisionis ad atomizandum et siccum solutionem specificae intentionis NaCl producendi particulas aerosolas ad magnitudinem et intentionem specificam.Ut late accommodare ad caelum nationalem, externum aerem fontem habet consilium, machinam siccat et valvae multi- COLLUM regulantem.Cum rate fluit aer inter 100L/min-120L/min est, ad output aerosol concentratio pervenire potest ad (10 -50 ) μg/m3.

  • ZR-1304 Aerosol generator

    ZR-1304 Aerosol generans

    ZR-1304 oleum aerosol generans est instrumentum speciale quod oleum aerosols generare potuit cum methodo generationis frigidae.Circumspecti aerosol intentionis ambitus est 0~200 mg/m³ cum airflow est 0~120 L/min, et intentionem aerosolam in amplis iugis diductionem fluens manually componendo accommodare potes.Executio aerosols conformia ad signa nationalia pertinentibus et applicata ad inspectionem Institutorum medicinae fabricam, centra morborum temperantiam et conservationem, societates pharmacopolia, detectio cinematographica HEPA in conclavia munda.

  • ZR-1220 Mask fit tester

    ZR-1220 Mask fit tester

    ZR-1220 larva aptum testor instrumentum speciale est ad idoneos exploratores larvarum et respiratorum, quae OSHA et GB 19083-2010 technicae requisita ad personas medicas conformant.Late applicatum est ad pertinentes probationes et inspectiones productorum respiratorum per artifices respiratores et laboris nationalis, instrumentorum tutelae institutionum inspectionis.

  • ZR-1211 Mask breath resistance tester

    ZR-1211 Mask resistentia spiritus testor

    ZR-1211 larva resistentiae testor adhibita est ad resistentiam inhalationem et exhalationem larvarum in condicione test regulari.Compatibile est multiplex rates fluere, idoneus est ad inspectionem et inspectionem larvarum pertinentium ad fabricas personas faciendas, instituta inspectionis nationalis ad machinas tutelae laboris.

  • ZR-1201 Mask resistance tester

    ZR-1201 Mask resistentia testor

    ZR-1201 larva resistentiae robustae conformis est YY 0469-2011.Methodum aerem fluxum adoptat ad probandum pressionem differentialem larvarum cum fluxus aeris extractus quandam ambitum larvae transeunt.Ad medicinae technas applicabilis Instituta inspectionis, artifices larvae et departments investigationis affinis.

  • ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester

    ZR-1006 Mask Efficientia particularis Filtration et Aeris Resistentia Tester

    ZR-1006 larva particularis filtrationis efficientiae et aeris fluxi resistentiae probatoris applicabilis est ad probandam particulam filtrationis efficientiam et aeris fluxum larvarum resistentiam et materias spargentium centra inspectionem machinae medicae, centrum inspectionis securitatis, centrum inspectionis medicamentorum, centra morborum temperantiam et praecaventiam; centrum inspectionis textilis, hospitalium et larvarum fabricantium R&D.

  • ZR-1002 mask particle protection effect tester

    ZR-1002 persona praesidium effectus testor

    Persona particula ZR-1002 effectus tutelae probatoris est probare particulam tutelae effectus larvarum, inserendo caput vexillum nationale ab in arca testi sui purgationis 500L, inde personam in capite gestare, et massam medianam diametri importare. 0.6 ± 0.050) µm, conducit 20mg / m³ naCl aerosol seu diametri mediae (0.3 ± 0.050) μm, conducit 20mg /m³ olei aerosol in auto-emundationem testam thalami sui, et caput forma spirans in sinuoideo curvatur. , photometris fluminis et amni utentes ad detegendam intentionem salis aerosol et olei aerosol ante et post larvam ad aestimandam particulam tutelae effectus larvae.

  • Mask Bacterial Filtration Efficiency (BFE) tester

    larva Bacterial Efficientia Filtration (BFE) tester

    Clavis specificationum exemplaris ZR-1000 larva bacteria filtrationis efficientiae probatoris (BFE) non solum cum requisitis B.1.1 in YY0469-2011sed etiam metus ASTMF2100, ASTMF2101 et signis Europae EN14683 occurrit.

  • Mask Viral Filtration Efficiency (VFE) Detector

    Mask Viral Filtration Efficiency (VFE) Detector

    Specificationes principales de ZR-1000A larva virus filtrationis efficientiae (VFE) probatoris conformis cum YY/T1497-2016 < Aestimatio experimenti methodi ad efficientiam viralem (VFE) de conservativa faciei medicae materiae larva-test methodo utendi bacteriophage Phi-X174 >, Methodus itineris gasi duplicis simultanei comparationis sampling accurationem sampling meliorit.